Calcium-45 (Ca-45)
Physical Data:
Pure Beta Emitter
|
|
258
keV (max.)
77.2 keV (avg.) |
- Radioactive Half Life
- Effective Half Life
- Biological Half Life
- Max. beta range in air
- Approximately
50% transmission rate through
dead layer of skin
|
162.61
days
162 days
1.8 x 104 days
47.91 cm |
Radiological Data:
- Critical organ: bone
- Internal exposure through ingestion, inhalation, or absorption
are primary concerns
- Dose rate to the basal cells from
skin contamination is approx. 2850 mr/hr µCi per
cm2
Shielding:
Survey Instrumentation:
- Liquid Scintillation Counter (LSC)
- LS window: 0 to 750
- LS efficiency: 100%
- Geiger - Mueller counter (efficiency
low)
Regulatory Compliance:
|
|
2000 µCi: (by ingestion)
8000 µCi: (by inhalation) |
|
|
4 x 10 -7 µCi/mL |
Special Considerations:
In general, Calcium-45 does not require any special precautions
over and above those necessary for any beta-emitting radionuclide
of this energy of emissions. The majority of Calicum-45
is deposited in the bone and is retained with a long biological
half life.
|
|
|
top
|